Stormbox
Stormbox II
Stormbox E
Stormbox II E
Infiltration Pipes
(version 1.0)
Pipelife - Infiltration tool
v.2
Infiltration program - 1.15
Austria
Bulgaria
Croatia
Czech Republic
Estonia
Finnish
France
Germany
Greece
Hungary
Latvia
Lithuania
Netherlands
Norway
Poland
Portugal
Romania
Serbia
Slovenia
Spain
Sweden
Turkey
United Kingdom
Project
The calculation of the size of the Stormbox tank for infiltration and attenuation installations are based on the German DWA A-138, ATV A-117 and the Dutch ISSO 70-1.
New installation calculations must be executed in case another product and in case another design is chosen.
Calculation for the dimensions of infiltration project for:
References:
Project properties
Region
England/Wales, r x 100 = 12
England/Wales, r x 100 = 15
England/Wales, r x 100 = 18
England/Wales, r x 100 = 21
England/Wales, r x 100 = 24
England/Wales, r x 100 = 27
England/Wales, r x 100 = 30
England/Wales, r x 100 = 33
England/Wales, r x 100 = 36
England/Wales, r x 100 = 39
England/Wales, r x 100 = 42
England/Wales, r x 100 = 45
Scotland/ N Ireland, r x 100 = 12
Scotland/ N Ireland, r x 100 = 15
Scotland/ N Ireland, r x 100 = 18
Scotland/ N Ireland, r x 100 = 21
Scotland/ N Ireland, r x 100 = 24
Scotland/ N Ireland, r x 100 = 27
Scotland/ N Ireland, r x 100 = 30
Scotland/ N Ireland, r x 100 = 33
Scotland/ N Ireland, r x 100 = 36
Scotland/ N Ireland, r x 100 = 39
Scotland/ N Ireland, r x 100 = 42
Scotland/ N Ireland, r x 100 = 45
Custom
Advice
Custom rain intensity data
Duration of
a shower
[minutes]
Rainfall [mm] for different return periods [years]
One overflow is allowed one time every
[years]
>= 0.5; < 100
Maximum width
[m]
>= 0.6m
Maximum height
[m]
>= 0.3m
Maximum length
[m]
>= 1.2m
Continuous inflow
[l/s]
Advice
Continuous outflow
[l/s]
Advice
Water infiltration speed into the soil
Gravel - 1000
Rough sand with fine gravel - 500
Rough sand - 50
Fine sand - 5
Best guess - 3
Very fine sand - 0.5
Loam containing sand - 0.05
Sandy clay - 0.0005
No infiltration - 0
Custom
[m/day]
[m/s]
[mm/h]
Advice
Custom infiltration speed
[m/day]
Advice
Installation
Application area
...
Landscaped area
Car parks
Lorry parks
Landscaped area with groundwater
Trafficked area with groundwater
Advice
Soil height A
[m]
Advice
Backfill soil type
Group 1 - non cohesive
Group 2 - slightly cohesive
Group 3 - mixed cohesive
Group 4 - cohesive
Backfill compaction
85%
90%
92%
Options
Shower factor:
Bottom infiltration
[%]
Sidewall infiltration
[%]
Connected surface area
Slant roofs (glaze)
[m²]
Slant roofs (ceramic/concrete)
[m²]
Flat roofs without gravel
[m²]
Flat roofs with gravel
[m²]
Vegetation roofs
[m²]
Asphalt road
[m²]
Brick road
[m²]
Road metal
[m²]
Gravel road
[m²]
Unpaved surfaces
[m²]
Parks and gardens
[m²]
Coefficient (<=1)
[m²]
[m²]
[m²]
[m²]
Prices
Price of a box
[Pound]
Price of a clip
[Pound]
Price of a bottom
[Pound]
Send data
Pipelife's proposal
ISSO 70-1
DWA-A138
No solution possible. Try increasing dimensions.
Project width
-
-
-
m
Project height
-
-
-
m
Project length
-
-
-
m
Gross project volume
-
m³
Net project volume
-
m³
Total surface to be covered
-
m²
Emptying time
-
hours
Critical Rain intensity
-
l/s/ha
Q Outflow
l/s
Stormbox - Number of boxes
-
Stormbox - Number of ground plates
-
Stormbox - Number of clips
-
Q (duration 15 minutes, 2 years)
-
l/s
Q (duration 15 minutes, 5 years)
-
l/s
Price
-
Pound
Continuous inflow
In this box an extra source of water going into the system can be defined in l/s.
×
Posible Solutions
Width
Height
Lenght
Boxes
Volume